The hardware and bandwidth for this mirror is donated by dogado GmbH, the Webhosting and Full Service-Cloud Provider. Check out our Wordpress Tutorial.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]dogado.de.

RLumModel - Getting started with RLumModel

Johannes Friedrich (University of Bayreuth, DE) & Sebastian Kreutzer (Geography and Earth Sciences, Aberystwyth University, UK)

2022-02-20

1 Introduction

This vignette shows a few examples for the R-package ‘RLumModel’. The main function model_LuminescenceSignals() and their arguments will be explained. All calculations were done with ‘RLumModel’ (version: 0.2.10) and ‘Luminescence’ (version: 0.9.19.9000.7).

2 Object structure of RLumModel

The output from the main function model_LuminescenceSignals() is of class RLum.Analysis (Kreutzer et al. 2012) and contains data of class RLum.Data.Curve in the slot ‘records’. The advantage of this infrastructure is that the package ‘Luminescence’ offers a lot of methods to visualize and manipulate data.

All simulated data are stored in the slot ‘records’: TL/OSL/RF curves as well as the concentrations of every energy level from every step.

The following code loads a data set provided by the ‘RLumModel’ package and shows how to separate TL/OSL/RF data from concentrations and how to visualize them.

data("ExampleData.ModelOutput", package = "RLumModel")

##show class
class(model.output)

##show structure
Luminescence::structure_RLum(model.output)

##separate TL-curve from TL-concentrations
TL_curve <- Luminescence::get_RLum(model.output, recordType = "TL$")
TL_conc <- Luminescence::get_RLum(model.output, recordType = "(TL)", drop = FALSE)

##also possible: TL_curve <- get_RLum(model.output, record.id = 1)

##plot results
Luminescence::plot_RLum(TL_curve)
Luminescence::plot_RLum(TL_conc)

Some notes to the code example above:

##plot every energy-level by an extra plot
Luminescence::plot_RLum(TL_conc, plot.single = TRUE)

It is also possible to choose a RLum.Data.Curve by their ‘record.id’, which can be seen with:

##see structure of model.output
Luminescence::structure_RLum(model.output)

3 Selecting a quartz luminescence model

The first argument required for the function model_LuminescenceSignals() is the name of a quartz luminescence model to be used, respectively the used parameter set in this quartz luminescence model. All currently implemented quartz luminescence models were described in Friedrich, Kreutzer, and Schmidt (2016). The command to select a set of parameters from a specific model in RLumModel is a character string with the name of the author and the year, e.g.

model <- "Bailey2001"

The available models are “Bailey2001”, “Bailey2002”, “Bailey2004”, “Pagonis2007”, “Pagonis2008”,“Friedrich2017” and “customized” (R. M. Bailey (2001), R. Bailey (2002), R. Bailey (2004), V. Pagonis, Chen, and Wintle (2007), V. Pagonis et al. (2008b), Friedrich et al. (2017)). For customized or own parameter sets, see vignette RLumModel - Using own parameter sets

The corresponding parameter set will be loaded automatically with the function call.

4 Creating a sequence

The second argument in the model_LuminescenceSignals() function is the sequence to be simulated. There are three different ways of creating a sequence.

For all sequences, temperature differences between sequence steps are automatically simulated with a heating or cooling step in between. Also, after irradiating the sample, it is automatically kept at irradiation temperature for further 5 s to allow the system to relax prior to the next step (R. M. Bailey 2001).

4.1 Risø SEQ files

The first one is to use the popular and freely available Risø to build a personal sequence and to save it as a SEQ-file (*.seq). Files created by the Sequence Editor can be imported directly using the path of the SEQ-file. The package comes along with an example SEQ-file in the package folder in ‘extdata’. Thus, a potential sequence is created with

sequence <- system.file(
  "extdata",
  "example_SAR_cycle.SEQ",
  package = "RLumModel")

or wherever the SEQ-file is stored. While in the Sequence Editor irradiation is commonly defined in seconds, performing the simulation requires a dose transformation to Gray. Therefore, the function model_LuminescenceSignals() offers a special argument called lab.dose_rate, representing the dose rate of the irradiation unit in the laboratory. By default, this dose rate is 1 Gy/s, but can be modified, e.g.,

lab.dose_rate <-  0.105

4.2 Keywords

The second way of creating a sequence is by referring to a list with keywords and a certain order of code numbers or named values, which are shown in Table 1. With these keywords, it is possible to create quickly an R object of type list, which can be read by the model_LuminescenceSignals() function.

Keywords in RLumModel for creating sequences
ARGUMENTS DESCRIPTION SUB-ARGUMENTS
TL Thermally stimulated luminescence ’temp_begin’ [°C], ’temp_end’ [°C], ’heating_rate’ [°C/s]
OSL Optically stimulated luminescence ’temp’ [°C], ’duration’ [s], ’optical_power’ [%]
ILL Illumination ’temp’ [°C], ’duration’ [s], ’optical_power’ [%]
LM_OSL Linear modulated OSL ’temp’ [°C], ’duration’ [s], optional: ’start_power’ [%], ’end_power’ [%]
RF Radiofluorescence ’temp’ [°C], ’dose’ [Gy], ’dose_rate’ [Gy/s]
RF_heating RF during heating/cooling ’temp_begin’ [°C], ’temp_end’ [°C], ‘heating rate’ [°C/s], ‘dose_rate’ [Gy/s]
IRR Irradiation ’temp’ [°C], ’dose’ [Gy], ’dose_rate’ [Gy/s]
CH Cutheat ’temp’ [°C], optional: ’duration’ [s], ’heating_rate’ [°C/s]
PH Preheat ’temp’ [°C], ’duration’ [s], optional: ’heating_rate’ [°C/s]
PAUSE Pause ’temp’ [°C], ’duration [s]’

Some examples to this kind of sequence creating:

sequence <- list(
 IRR = c(temp = 20, dose = 10, dose_rate = 1),
 TL = c(temp_begin = 20, temp_end = 400 , heating_rate = 5))

This sequences describes an irradiation simulation at 20 °C with a dose of 10 Gy and a dose rate of 1 Gy/s, which is followed by a TL simulation from 20 °C to 400 °C with a heating rate of 5 °C/s. Note that it is important that for each sequence keyword like ‘IRR’ or ‘TL’ either the vector has to be named or the correct order of arguments is used, see ‘sub-arguments’ in Table 1. Thus the above mentioned code is equivalent to the following one:

sequence <- list(
  IRR = c(20, 10, 1),
  TL = c(20, 400, 5))

4.3 Creating a SAR/DRT sequence

However, to create a SAR or dose-recovery-test (DRT) sequence with the Risø Sequence Editor or with keywords is time-consuming, because it contains a lot of individual sequence steps (preheat, optical stimulation, irradiation, …). Therefore, a third way was implemented in ‘RLumModel’ to create a (SAR) sequence after Murray and Wintle (2000) with the (required) keywords RegDose, TestDose, PH, CH and OSL temp. In addition to these keywords, the user is able to set more detailed parameters for the SAR sequence, see Table 2:

Keywords in RLumModel for creating SAR sequences
ABBREVIATION DESCRIPTION EXAMPLE ARGUMENTS
RegDose Dose points of the regenerative cycles [Gy] c(0, 80, 140, 260, 320, 0, 80)
TestDose Test dose for the SAR cycles [Gy] 50
PH Temperature of the preheat [°C] 240
CH Temperature of the cutheat [°C] 200
OSL_temp Temperature of OSL read out [°C] 125
OSL_duration Duration of OSL read out [s] default: 40
Irr_temp Temperature of irradiation [°C] default: 20
PH_duration Duration of the preheat [s] default: 10
dose_rate Dose rate of the laboratory irradiation source [Gy/s] default: 1
optical_power Percentage of the full illumination power [%] default: 90
Irr_2recover Dose to be recovered in a dose-recovery-test [Gy] 20

So a possible DRT sequence could be the next code example:

sequence <- list(
  RegDose = c(0,10,20,50,90,0,10),
  TestDose = 2,
  PH = 220,
  CH = 220,
  OSL_temp = 125,
  Irr_2recover = 20)

This sequence describes a DRT, where a dose of 20 Gy will be recovered with this test. The regenerative doses are defined as 0 (natural), 10 Gy, 20 Gy, 50 Gy, 90 Gy and for recuperation and recycling ratio 0 Gy and 10 Gy, respectively. The test dose is defined as 2 Gy. Preheat and cutheat are at 220 °C and all OSL measurements are simulated at 125 °C. There are more options to set, see Table 2.

The ‘RLumModel’ function model_LuminescenceSignals() is able to interpret this (sequence-) list as a DRT sequence.

5 Working examples

5.1 Simulate a TL measurement

First of all, a sequence is needed, which produces a TL signal after the sample has received a dose:

sequence <- list (
IRR = c (20 , 10 , 1) ,
TL = c (20 , 400 , 5))

Here, at a temperature of 20 °C a dose of 10 Gy was applied with a dose rate of 1 Gy/s followed by a TL measurement from 20 °C to 400 °C with a heating rate of 5 °C/s. Running this sequence with the model_LuminescenceSignals() function produces a model output:

model.output <- model_LuminescenceSignals(
  model = "Bailey2001",
  sequence = sequence,
  verbose = FALSE)
TL curve with parameter set 'Bailey2001' after 10 Gy laboratory dose

TL curve with parameter set ‘Bailey2001’ after 10 Gy laboratory dose

This results in a TL curve like the one published in (R. M. Bailey (2001), Fig. 1), see figure above. In a further step, it is easy to produce known TL phenomena like the shift of the TL peak with varying heating rate. For this purpose, a loop over a TL simulation changes the heating rate in each run.

##set heating rate
heating.rate <- seq(from = 2, to = 10, by = 2)

##model signals
##"verbose = FALSE" for no terminal output
## "TL$" for exact matching TL and not (TL)
model.output <- lapply(heating.rate, function(x){
  sequence <- list(
   IRR = c(20, 10, 1),
   TL = c(20, 400, x))


  TL_data <- model_LuminescenceSignals(
      sequence = sequence,
      model = "Bailey2001",
      plot = FALSE,
      verbose = FALSE)
  
  return(Luminescence::get_RLum(TL_data, recordType = "TL$", drop = FALSE))

})

##merge output
model.output.merged <- merge_RLum(model.output)

##plot results
plot_RLum(
 object = model.output.merged,
 xlab = "Temperature [\u00B0C]",
 ylab = "TL signal [a.u.]",
 main = "TL signal with different heating rates",
 legend.text = paste(heating.rate, "°C/s"),
 combine = TRUE)
TL signal with different heating rates

TL signal with different heating rates

Some notes to the code above:

5.2 Simulating thermal activation characteristics (TACs)

Another frequently simulated phenomenon is the sensitisation of quartz TL by \(\beta\)- or \(\gamma\)-irradiation followed by activation at high temperatures Adamiec et al. (2004), termed as thermal activation characteristics (TACs). For a simulation sequence, the reader is referred to V. Pagonis et al. (2008a), Tab. 1. To simulate this phenomenon with the model_LuminescenceSignals() function, a loop causing a stepwise increase of the activation temperature is needed. The resulting intensity of the 110 °C TL peak can be plotted against the activation temperature, which shows TAC for the model parameters of “Pagonis2007”.

##set temperature
act.temp <- seq(from = 80, to = 600, by = 20)

##loop over temperature
model.output <- vapply(X = act.temp, FUN = function(x) {
  
  ##set sequence, note: sequence includes sample history
  sequence <- list(
    IRR = c(20, 1, 1e-11),
    IRR = c(20, 10, 1),
    PH = c(x, 1),
    IRR = c(20, 0.1, 1),
    TL = c(20, 150, 5)
    )

  ##run simulation
  temp <- model_LuminescenceSignals(
    sequence = sequence,
    model = "Pagonis2007",
    simulate_sample_history = TRUE,
    plot = FALSE,
    verbose = FALSE
    )
  
  ## "TL$" for exact matching TL and not (TL)
  TL_curve <- Luminescence::get_RLum(temp, recordType = "TL$")

  ##return max value in TL curve
  return(max(get_RLum(TL_curve)[,2]))

}, FUN.VALUE = 1)
TAC with parameter set of 'Pagonis2007'

TAC with parameter set of ‘Pagonis2007’

5.3 Simulating dependency of the OSL signal on the illumination power density

The function model_LuminescenceSignals() is also capable of simulating OSL phenomena. The next figure shows the dependency of the OSL signal on the power density of illumination for the model “Bailey2004”.

##set optical power [%]
optical_power <- c(0,20,40,60,80,100)

##loop over power 
model.output <- lapply(optical_power, function(x){

  ##set sequence
  sequence <- list(
    IRR = c(20, 50, 1),
    PH = c(220, 10, 5),
    OSL = c(125, 50, x))

  
  data <-  model_LuminescenceSignals(
    sequence = sequence,
    model = "Bailey2004",
    plot = FALSE,
    verbose = FALSE)
  
  ##"OSL$" for exact matching OSL and not (OSL)
  return(Luminescence::get_RLum(data, recordType = "OSL$", drop = FALSE))
  
})

##merge output
model.output.merged <- Luminescence::merge_RLum(model.output)

##plot results
Luminescence::plot_RLum(
  object = model.output.merged,
  xlab = "Illumination time [s]",
  ylab = "OSL signal [a.u.]",
  legend.text = paste("Optical power ", 20 * optical_power / 100," mW/cm^2"),
  combine = TRUE 
  )
OSL measurement with different optical power densities with the parameter set of 'Bailey2004'

OSL measurement with different optical power densities with the parameter set of ‘Bailey2004’

5.4 Simulating and analysing SAR measurements

For simulating a DRT, it is necessary to define a sequence with the keyword Irr_2recover, as mentioned in Section 4.3.

It should be mentioned that a simulation of a combinded PHPT and DRT may be very time-consuming, because for every preheat temperature a complete SAR cycle has to be run. A typical DRT sequence featuring various PH temperatures in ‘RLumModel’ is listed below. Note that in such a DRT simulation a loop over different preheat temperatures has to be written, utilising characteristic parameters from the literature. The test dose is set to 10% and the regeneration dose points to 40%, 70%, 130%, 160%, 0% and 40% of the recovery dose.

The data created by ‘RLumModel’ can be directly passed to the functions Luminescence::analyse_SAR.CWOSL() and Luminescence::plot_DRTResults() for routine analyses and plotting.

##set PH temperatures
PH_temp <- seq(from = 160, to = 300, by = 20)

##set regeneration doses
RegDose = c(0, 80, 140, 260, 320, 0, 80)

##loop over PH temperatures
DRT.output <- lapply(PH_temp, function(x){

  sequence <- list(
       RegDose = RegDose,
       TestDose = 20,
       PH = x,
       CH = x,
       OSL_temp = 125,
       Irr_2recover = 200)

  model.output <- model_LuminescenceSignals(
       sequence = sequence,
       model = "Pagonis2008",
       plot = FALSE,
       verbose = FALSE)

  results <- Luminescence::analyse_SAR.CWOSL(
       object = model.output,
       signal.integral.min = 1,
       signal.integral.max = 7,
       background.integral.min = 301,
       background.integral.max = 401,
       fit.method = "EXP",
       dose.points = RegDose,
       plot = FALSE)
                                                            
  temp <- get_RLum(results)
  out <- data.frame(
    De = temp$De, 
    De.error = temp$De.Error)
    
  return(out)
})
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 179.1 | D01 = 101.51
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 179.46 | D01 = 101.46
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 180.18 | D01 = 101.4
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 180.6 | D01 = 101.41
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 182.24 | D01 = 101.44
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 179.85 | D01 = 102.26
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 166.73 | D01 = 111.51
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 159.15 | D01 = 161.2
##output as data.frame for plot_DRTResults
DRT.result <- as.data.frame(do.call(rbind, DRT.output))

##plot DRT.results
Luminescence::plot_DRTResults(
     DRT.result, 
     preheat = PH_temp,
     given.dose = 200)
Dose recovery test (DRT) with the parameter set of 'Pagonis2008'

Dose recovery test (DRT) with the parameter set of ‘Pagonis2008’

In the code above, plot = FALSE was chosen, because a single OSL plot is not necessary to analyse a SAR sequence. To calculate a De from the produced RLum.Analysis object ‘model.output’, the function Luminescence::analyse_SAR.CWOSL() is suitable. After specifying a number of evaluation parameters (signal and background integration interval, dose points and fit function for the dose response curve) and the analysis process, the reduced data are stored in an RLum.Results object, here termed ‘results’ . A background integration interval from 301 to 401 translates to the signal from 30 s to 40 s, because a channel has the default width of 0.1 s. Accordingly, the signal integral ranges from 0.1 s to 0.7 s.

##set RegDose
RegDose = c(0, 80, 140, 260, 320, 0, 80)

##set sequence
sequence <- list(
  RegDose = RegDose,
  TestDose = 20,
  PH = 220,
  CH = 220,
  OSL_temp = 125
  )

##model 
model.output <- model_LuminescenceSignals(
  sequence = sequence,
  model = "Pagonis2008",
  plot = FALSE,
  verbose = FALSE
  )
        
##analyse SAR sequence and plot only the resulting growth curve 
results <- Luminescence::analyse_SAR.CWOSL(
  model.output,
  signal.integral.min = 1,
  signal.integral.max = 7,
  background.integral.min = 301,
  background.integral.max = 401,
  fit.method = "EXP",
  dose.points = RegDose, 
  verbose = FALSE, 
  plot.single = c(6)
  )
SAR protocol with the parameter set of 'Pagonis2008'

SAR protocol with the parameter set of ‘Pagonis2008’

6 Miscellaneous

6.1 Accessing applied modelling parameters

Sometimes it is useful to extract the used modelling parameters. Since the output is an RLum.Analysis-object compatible with the R package 'Luminescence', this can be achieved with the following code lines (note: we have shorted the terminal output below using the function head()):

head(Luminescence::get_RLum(model.output, info = "parms"))
## $parms.N1
## [1] 1.5e+07
## 
## $parms.N2
## [1] 1e+07
## 
## $parms.N3
## [1] 4e+07
## 
## $parms.N4
## [1] 2.5e+08
## 
## $parms.N5
## [1] 5e+10
## 
## $parms.N6
## [1] 5e+09

6.2 Trace parameter state evolution

An exciting feature of 'RLumModel' is that it allows you to gain insight into the evolution of different parameter states beyond a single simulation, which would show you how numerical parameters change if the solver runs over the equations. For instance, assume you have a sequence of different stimulation steps (TL, OSL etc.). You want to know how the system, for which the solver has to find a solution, changes from one sequence step to another. This is of interest because the initial state of the system of each step will determine the shape of the curve. Let’s think of the following sequence that, after an initial TL readout, adds a dose followed by a TL measurement, then another irradiation, another TL measurement and so on.

dose_points <- seq(8,600, length.out = 50)
sequence <- c(
  list(TL = c(20 , 500 , 2)),
  unlist(lapply(dose_points, function(d){
    list(
      IRR = c(20 , d , 0.03),
      TL = c(20 , 250, 2))
    
  }), recursive = FALSE)) 

This sequence can modelled as shown above, here we use again the Baily2001 model:

results <- model_LuminescenceSignals(
  model = "Bailey2001",
  sequence = sequence,
  plot = FALSE,
  show_structure = FALSE,
  simulate_sample_history = FALSE,
  verbose = FALSE) 

What we did already above was to show the resulting TL curves, and we do this again, just to see how they look like.

Luminescence::plot_RLum(
  get_RLum(results, recordType = "^TL$", drop = FALSE),
  combine = TRUE,
  xlim = c(20,120), 
  records_max = 10,
  legend.pos = "topleft",
  plot.single = TRUE)

Now we go one step further and focus our interest on the evolution of each parameter set at the end of each sequence step. Extracting all the data manually is possible, but a little cumbersome, so instead, we will use the function trace_StateParameterEvoluation() (this function was introduced with 'RLumModel' v0.2.10).

trace_ParameterStateEvolution(results)

References

Adamiec, Grzegorz, Marta Garcia-Talavera, Richard M Bailey, and Pilar Iniguez de La Torre. 2004. “Application of a Genetic Algorithm to Finding Parameter Values for Numerical Simulation of Quartz Luminescence.” Geochronometria 23: 9–14.
Bailey, R M. 2001. “Towards a General Kinetic Model for Optically and Thermally Stimulated Luminescence of Quartz.” Radiation Measurements 33: 17–45.
Bailey, R. 2002. “Simulations of Variability in the Luminescence Characteristics of Natural Quartz and Its Implications for Estimates of Absorbed Dose.” Radiation Protection Dosimetry 100: 33–38.
———. 2004. Paper I - Simulation of dose absorption in quartz over geological timescales and its implications for the precision and accuracy of optical dating.” Radiation Measurements 38: 299–310.
Friedrich, Johannes, Sebastian Kreutzer, and Christoph Schmidt. 2016. Solving ordinary differential equations to understand luminescence: ’RLumModel’, an advanced research tool for simulating luminescence in quartz using R .” Quaternary Geochronology 35: 88–100.
Friedrich, Johannes, Vasilis Pagonis, Reuven Chen, Sebastian Kreutzer, and Christoph Schmidt. 2017. “Quartz Radiofluorescence: A Modelling Approach.” Journal of Luminescence 186: 318–25.
Kreutzer, Sebastian, Christoph Schmidt, Margret C Fuchs, Michael Dietze, Manfred Fischer, and Markus Fuchs. 2012. Introducing an R package for luminescence dating analysis.” Ancient TL 30: 1–8.
Pagonis, Vasilis, George Kitis, and Reuven Chen. 2003. Applicability of the Zimmerman predose model in the thermoluminescence of predosed and annealed synthetic quartz samples.” Radiation Measurements 37 (3): 267–74.
Pagonis, V, E Balsamo, C Barnold, K Duling, and S McCole. 2008a. “Simulations of the Predose Technique for Retrospective Dosimetry and Authenticity Testing.” Radiation Measurements 43 (8): 1343–53.
Pagonis, V, R Chen, and AG Wintle. 2007. “Modelling Thermal Transfer in Optically Stimulated Luminescence of Quartz.” Journal of Physics D: Applied Physics 40 (4): 998.
Pagonis, V., A. G. Wintle, R. Chen, and X. L. Wang. 2008b. A theoretical model for a new dating protocol for quartz based on thermally transferred OSL (TT-OSL).” Radiation Measurements 43: 704–8.
Zimmerman, J. 1971. “The Radiation-Induced Increase of the 100\(\,^\circ\)c Thermoluminescence Sensitivity of Fired Quartz.” Journal of Physics C: Solid State Physics 4 (18): 3265–76.

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.
Health stats visible at Monitor.