The hardware and bandwidth for this mirror is donated by dogado GmbH, the Webhosting and Full Service-Cloud Provider. Check out our Wordpress Tutorial.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]dogado.de.
This vignette shows a few examples for the R-package
‘RLumModel’. The main function model_LuminescenceSignals()
and their arguments will be explained. All calculations were done with
‘RLumModel’ (version: 0.2.10) and ‘Luminescence’ (version:
0.9.19.9000.7).
The output from the main function
model_LuminescenceSignals()
is of class
RLum.Analysis
(Kreutzer et al.
2012) and contains data of class RLum.Data.Curve
in
the slot ‘records’. The advantage of this infrastructure is that the
package ‘Luminescence’ offers a lot of methods to visualize and
manipulate data.
All simulated data are stored in the slot ‘records’: TL/OSL/RF curves as well as the concentrations of every energy level from every step.
The following code loads a data set provided by the ‘RLumModel’ package and shows how to separate TL/OSL/RF data from concentrations and how to visualize them.
data("ExampleData.ModelOutput", package = "RLumModel")
##show class
class(model.output)
##show structure
::structure_RLum(model.output)
Luminescence
##separate TL-curve from TL-concentrations
<- Luminescence::get_RLum(model.output, recordType = "TL$")
TL_curve <- Luminescence::get_RLum(model.output, recordType = "(TL)", drop = FALSE)
TL_conc
##also possible: TL_curve <- get_RLum(model.output, record.id = 1)
##plot results
::plot_RLum(TL_curve)
Luminescence::plot_RLum(TL_conc) Luminescence
Some notes to the code example above:
drop = FALSE
was used to keep the
RLum.Analysis
class for ‘TL_conc’.plot.single = TRUE
in plot_RLum()
. For more
details see the manual of ‘Luminescence’.##plot every energy-level by an extra plot
::plot_RLum(TL_conc, plot.single = TRUE) Luminescence
It is also possible to choose a RLum.Data.Curve
by their
‘record.id’, which can be seen with:
##see structure of model.output
::structure_RLum(model.output) Luminescence
The first argument required for the function
model_LuminescenceSignals()
is the name of a quartz
luminescence model to be used, respectively the used parameter set in
this quartz luminescence model. All currently implemented quartz
luminescence models were described in Friedrich,
Kreutzer, and Schmidt (2016). The command to select a set of
parameters from a specific model in RLumModel
is a
character string with the name of the author and the year, e.g.
<- "Bailey2001" model
The available models are “Bailey2001”, “Bailey2002”, “Bailey2004”, “Pagonis2007”, “Pagonis2008”,“Friedrich2017” and “customized” (R. M. Bailey (2001), R. Bailey (2002), R. Bailey (2004), V. Pagonis, Chen, and Wintle (2007), V. Pagonis et al. (2008b), Friedrich et al. (2017)). For customized or own parameter sets, see vignette RLumModel - Using own parameter sets
The corresponding parameter set will be loaded automatically with the function call.
The second argument in the model_LuminescenceSignals()
function is the sequence to be simulated. There are three different ways
of creating a sequence.
For all sequences, temperature differences between sequence steps are automatically simulated with a heating or cooling step in between. Also, after irradiating the sample, it is automatically kept at irradiation temperature for further 5 s to allow the system to relax prior to the next step (R. M. Bailey 2001).
The first one is to use the popular and freely available Risø to build a personal sequence and to save it as a SEQ-file (*.seq). Files created by the Sequence Editor can be imported directly using the path of the SEQ-file. The package comes along with an example SEQ-file in the package folder in ‘extdata’. Thus, a potential sequence is created with
<- system.file(
sequence "extdata",
"example_SAR_cycle.SEQ",
package = "RLumModel")
or wherever the SEQ-file is stored. While in the Sequence Editor
irradiation is commonly defined in seconds, performing the simulation
requires a dose transformation to Gray. Therefore, the function
model_LuminescenceSignals()
offers a special argument
called lab.dose_rate
, representing the dose rate of the
irradiation unit in the laboratory. By default, this dose rate is 1
Gy/s, but can be modified, e.g.,
<- 0.105 lab.dose_rate
The second way of creating a sequence is by referring to a list with
keywords and a certain order of code numbers or named values, which are
shown in Table 1. With these keywords, it is possible to create quickly
an R object of type list, which can be read by the
model_LuminescenceSignals()
function.
ARGUMENTS | DESCRIPTION | SUB-ARGUMENTS |
---|---|---|
TL | Thermally stimulated luminescence | ’temp_begin’ [°C], ’temp_end’ [°C], ’heating_rate’ [°C/s] |
OSL | Optically stimulated luminescence | ’temp’ [°C], ’duration’ [s], ’optical_power’ [%] |
ILL | Illumination | ’temp’ [°C], ’duration’ [s], ’optical_power’ [%] |
LM_OSL | Linear modulated OSL | ’temp’ [°C], ’duration’ [s], optional: ’start_power’ [%], ’end_power’ [%] |
RF | Radiofluorescence | ’temp’ [°C], ’dose’ [Gy], ’dose_rate’ [Gy/s] |
RF_heating | RF during heating/cooling | ’temp_begin’ [°C], ’temp_end’ [°C], ‘heating rate’ [°C/s], ‘dose_rate’ [Gy/s] |
IRR | Irradiation | ’temp’ [°C], ’dose’ [Gy], ’dose_rate’ [Gy/s] |
CH | Cutheat | ’temp’ [°C], optional: ’duration’ [s], ’heating_rate’ [°C/s] |
PH | Preheat | ’temp’ [°C], ’duration’ [s], optional: ’heating_rate’ [°C/s] |
PAUSE | Pause | ’temp’ [°C], ’duration [s]’ |
Some examples to this kind of sequence creating:
<- list(
sequence IRR = c(temp = 20, dose = 10, dose_rate = 1),
TL = c(temp_begin = 20, temp_end = 400 , heating_rate = 5))
This sequences describes an irradiation simulation at 20 °C with a dose of 10 Gy and a dose rate of 1 Gy/s, which is followed by a TL simulation from 20 °C to 400 °C with a heating rate of 5 °C/s. Note that it is important that for each sequence keyword like ‘IRR’ or ‘TL’ either the vector has to be named or the correct order of arguments is used, see ‘sub-arguments’ in Table 1. Thus the above mentioned code is equivalent to the following one:
<- list(
sequence IRR = c(20, 10, 1),
TL = c(20, 400, 5))
However, to create a SAR or dose-recovery-test (DRT) sequence with the Risø Sequence Editor or with keywords is time-consuming, because it contains a lot of individual sequence steps (preheat, optical stimulation, irradiation, …). Therefore, a third way was implemented in ‘RLumModel’ to create a (SAR) sequence after Murray and Wintle (2000) with the (required) keywords RegDose, TestDose, PH, CH and OSL temp. In addition to these keywords, the user is able to set more detailed parameters for the SAR sequence, see Table 2:
ABBREVIATION | DESCRIPTION | EXAMPLE ARGUMENTS |
---|---|---|
RegDose | Dose points of the regenerative cycles [Gy] | c(0, 80, 140, 260, 320, 0, 80) |
TestDose | Test dose for the SAR cycles [Gy] | 50 |
PH | Temperature of the preheat [°C] | 240 |
CH | Temperature of the cutheat [°C] | 200 |
OSL_temp | Temperature of OSL read out [°C] | 125 |
OSL_duration | Duration of OSL read out [s] | default: 40 |
Irr_temp | Temperature of irradiation [°C] | default: 20 |
PH_duration | Duration of the preheat [s] | default: 10 |
dose_rate | Dose rate of the laboratory irradiation source [Gy/s] | default: 1 |
optical_power | Percentage of the full illumination power [%] | default: 90 |
Irr_2recover | Dose to be recovered in a dose-recovery-test [Gy] | 20 |
So a possible DRT sequence could be the next code example:
<- list(
sequence RegDose = c(0,10,20,50,90,0,10),
TestDose = 2,
PH = 220,
CH = 220,
OSL_temp = 125,
Irr_2recover = 20)
This sequence describes a DRT, where a dose of 20 Gy will be recovered with this test. The regenerative doses are defined as 0 (natural), 10 Gy, 20 Gy, 50 Gy, 90 Gy and for recuperation and recycling ratio 0 Gy and 10 Gy, respectively. The test dose is defined as 2 Gy. Preheat and cutheat are at 220 °C and all OSL measurements are simulated at 125 °C. There are more options to set, see Table 2.
The ‘RLumModel’ function model_LuminescenceSignals()
is
able to interpret this (sequence-) list as a DRT sequence.
First of all, a sequence is needed, which produces a TL signal after the sample has received a dose:
<- list (
sequence IRR = c (20 , 10 , 1) ,
TL = c (20 , 400 , 5))
Here, at a temperature of 20 °C a dose of 10 Gy was applied with a
dose rate of 1 Gy/s followed by a TL measurement from 20 °C to 400 °C
with a heating rate of 5 °C/s. Running this sequence with the
model_LuminescenceSignals()
function produces a model
output:
<- model_LuminescenceSignals(
model.output model = "Bailey2001",
sequence = sequence,
verbose = FALSE)
This results in a TL curve like the one published in (R. M. Bailey (2001), Fig. 1), see figure above. In a further step, it is easy to produce known TL phenomena like the shift of the TL peak with varying heating rate. For this purpose, a loop over a TL simulation changes the heating rate in each run.
##set heating rate
<- seq(from = 2, to = 10, by = 2)
heating.rate
##model signals
##"verbose = FALSE" for no terminal output
## "TL$" for exact matching TL and not (TL)
<- lapply(heating.rate, function(x){
model.output <- list(
sequence IRR = c(20, 10, 1),
TL = c(20, 400, x))
<- model_LuminescenceSignals(
TL_data sequence = sequence,
model = "Bailey2001",
plot = FALSE,
verbose = FALSE)
return(Luminescence::get_RLum(TL_data, recordType = "TL$", drop = FALSE))
})
##merge output
<- merge_RLum(model.output)
model.output.merged
##plot results
plot_RLum(
object = model.output.merged,
xlab = "Temperature [\u00B0C]",
ylab = "TL signal [a.u.]",
main = "TL signal with different heating rates",
legend.text = paste(heating.rate, "°C/s"),
combine = TRUE)
Some notes to the code above:
RLum.Analysis
object, because of drop = FALSErecordType = TL$
is necessary to match the character TL
exact and not the concentrationsmerge_RLum
is necessary to merge all the single
RLum.Analysis
objects in the list ‘model.output’ together
to one RLum.Analysis
objectmodel = "..."
has to be changed (see Sec. 2)Another frequently simulated phenomenon is the sensitisation of
quartz TL by \(\beta\)- or \(\gamma\)-irradiation followed by activation
at high temperatures Adamiec et al.
(2004), termed as thermal activation characteristics (TACs). For
a simulation sequence, the reader is referred to V. Pagonis et al. (2008a), Tab. 1. To simulate
this phenomenon with the model_LuminescenceSignals()
function, a loop causing a stepwise increase of the activation
temperature is needed. The resulting intensity of the 110 °C TL peak can
be plotted against the activation temperature, which shows TAC for the
model parameters of “Pagonis2007”.
##set temperature
<- seq(from = 80, to = 600, by = 20)
act.temp
##loop over temperature
<- vapply(X = act.temp, FUN = function(x) {
model.output
##set sequence, note: sequence includes sample history
<- list(
sequence IRR = c(20, 1, 1e-11),
IRR = c(20, 10, 1),
PH = c(x, 1),
IRR = c(20, 0.1, 1),
TL = c(20, 150, 5)
)
##run simulation
<- model_LuminescenceSignals(
temp sequence = sequence,
model = "Pagonis2007",
simulate_sample_history = TRUE,
plot = FALSE,
verbose = FALSE
)
## "TL$" for exact matching TL and not (TL)
<- Luminescence::get_RLum(temp, recordType = "TL$")
TL_curve
##return max value in TL curve
return(max(get_RLum(TL_curve)[,2]))
FUN.VALUE = 1) },
The function model_LuminescenceSignals()
is also capable
of simulating OSL phenomena. The next figure shows the dependency of the
OSL signal on the power density of illumination for the model
“Bailey2004”.
##set optical power [%]
<- c(0,20,40,60,80,100)
optical_power
##loop over power
<- lapply(optical_power, function(x){
model.output
##set sequence
<- list(
sequence IRR = c(20, 50, 1),
PH = c(220, 10, 5),
OSL = c(125, 50, x))
<- model_LuminescenceSignals(
data sequence = sequence,
model = "Bailey2004",
plot = FALSE,
verbose = FALSE)
##"OSL$" for exact matching OSL and not (OSL)
return(Luminescence::get_RLum(data, recordType = "OSL$", drop = FALSE))
})
##merge output
<- Luminescence::merge_RLum(model.output)
model.output.merged
##plot results
::plot_RLum(
Luminescenceobject = model.output.merged,
xlab = "Illumination time [s]",
ylab = "OSL signal [a.u.]",
legend.text = paste("Optical power ", 20 * optical_power / 100," mW/cm^2"),
combine = TRUE
)
For simulating a DRT, it is necessary to define a sequence with the
keyword Irr_2recover
, as mentioned in Section 4.3.
It should be mentioned that a simulation of a combinded PHPT and DRT may be very time-consuming, because for every preheat temperature a complete SAR cycle has to be run. A typical DRT sequence featuring various PH temperatures in ‘RLumModel’ is listed below. Note that in such a DRT simulation a loop over different preheat temperatures has to be written, utilising characteristic parameters from the literature. The test dose is set to 10% and the regeneration dose points to 40%, 70%, 130%, 160%, 0% and 40% of the recovery dose.
The data created by ‘RLumModel’ can be directly passed to the
functions Luminescence::analyse_SAR.CWOSL()
and
Luminescence::plot_DRTResults()
for routine analyses and
plotting.
##set PH temperatures
<- seq(from = 160, to = 300, by = 20)
PH_temp
##set regeneration doses
= c(0, 80, 140, 260, 320, 0, 80)
RegDose
##loop over PH temperatures
<- lapply(PH_temp, function(x){
DRT.output
<- list(
sequence RegDose = RegDose,
TestDose = 20,
PH = x,
CH = x,
OSL_temp = 125,
Irr_2recover = 200)
<- model_LuminescenceSignals(
model.output sequence = sequence,
model = "Pagonis2008",
plot = FALSE,
verbose = FALSE)
<- Luminescence::analyse_SAR.CWOSL(
results object = model.output,
signal.integral.min = 1,
signal.integral.max = 7,
background.integral.min = 301,
background.integral.max = 401,
fit.method = "EXP",
dose.points = RegDose,
plot = FALSE)
<- get_RLum(results)
temp <- data.frame(
out De = temp$De,
De.error = temp$De.Error)
return(out)
})
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 179.1 | D01 = 101.51
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 179.46 | D01 = 101.46
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 180.18 | D01 = 101.4
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 180.6 | D01 = 101.41
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 182.24 | D01 = 101.44
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 179.85 | D01 = 102.26
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 166.73 | D01 = 111.51
## [plot_GrowthCurve()] Fit: EXP (interpolation) | De = 159.15 | D01 = 161.2
##output as data.frame for plot_DRTResults
<- as.data.frame(do.call(rbind, DRT.output))
DRT.result
##plot DRT.results
::plot_DRTResults(
Luminescence
DRT.result, preheat = PH_temp,
given.dose = 200)
In the code above, plot = FALSE
was chosen, because a
single OSL plot is not necessary to analyse a SAR sequence. To calculate
a De from the produced RLum.Analysis
object
‘model.output’, the function
Luminescence::analyse_SAR.CWOSL()
is suitable. After
specifying a number of evaluation parameters (signal and background
integration interval, dose points and fit function for the dose response
curve) and the analysis process, the reduced data are stored in an
RLum.Results
object, here termed ‘results’ . A background
integration interval from 301 to 401 translates to the signal from 30 s
to 40 s, because a channel has the default width of 0.1 s. Accordingly,
the signal integral ranges from 0.1 s to 0.7 s.
##set RegDose
= c(0, 80, 140, 260, 320, 0, 80)
RegDose
##set sequence
<- list(
sequence RegDose = RegDose,
TestDose = 20,
PH = 220,
CH = 220,
OSL_temp = 125
)
##model
<- model_LuminescenceSignals(
model.output sequence = sequence,
model = "Pagonis2008",
plot = FALSE,
verbose = FALSE
)
##analyse SAR sequence and plot only the resulting growth curve
<- Luminescence::analyse_SAR.CWOSL(
results
model.output,signal.integral.min = 1,
signal.integral.max = 7,
background.integral.min = 301,
background.integral.max = 401,
fit.method = "EXP",
dose.points = RegDose,
verbose = FALSE,
plot.single = c(6)
)
Sometimes it is useful to extract the used modelling parameters.
Since the output is an RLum.Analysis
-object compatible with
the R package 'Luminescence'
, this can be achieved with the
following code lines (note: we have shorted the terminal output below
using the function head()
):
head(Luminescence::get_RLum(model.output, info = "parms"))
## $parms.N1
## [1] 1.5e+07
##
## $parms.N2
## [1] 1e+07
##
## $parms.N3
## [1] 4e+07
##
## $parms.N4
## [1] 2.5e+08
##
## $parms.N5
## [1] 5e+10
##
## $parms.N6
## [1] 5e+09
An exciting feature of 'RLumModel'
is that it allows you
to gain insight into the evolution of different parameter states beyond
a single simulation, which would show you how numerical parameters
change if the solver runs over the equations. For instance, assume you
have a sequence of different stimulation steps (TL, OSL etc.). You want
to know how the system, for which the solver has to find a solution,
changes from one sequence step to another. This is of interest because
the initial state of the system of each step will determine the shape of
the curve. Let’s think of the following sequence that, after an initial
TL readout, adds a dose followed by a TL measurement, then another
irradiation, another TL measurement and so on.
<- seq(8,600, length.out = 50)
dose_points <- c(
sequence list(TL = c(20 , 500 , 2)),
unlist(lapply(dose_points, function(d){
list(
IRR = c(20 , d , 0.03),
TL = c(20 , 250, 2))
recursive = FALSE)) }),
This sequence can modelled as shown above, here we use again the
Baily2001
model:
<- model_LuminescenceSignals(
results model = "Bailey2001",
sequence = sequence,
plot = FALSE,
show_structure = FALSE,
simulate_sample_history = FALSE,
verbose = FALSE)
What we did already above was to show the resulting TL curves, and we do this again, just to see how they look like.
::plot_RLum(
Luminescenceget_RLum(results, recordType = "^TL$", drop = FALSE),
combine = TRUE,
xlim = c(20,120),
records_max = 10,
legend.pos = "topleft",
plot.single = TRUE)
Now we go one step further and focus our interest on the evolution of
each parameter set at the end of each sequence step. Extracting all the
data manually is possible, but a little cumbersome, so instead, we will
use the function trace_StateParameterEvoluation()
(this
function was introduced with 'RLumModel'
v0.2.10).
trace_ParameterStateEvolution(results)
These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.
Health stats visible at Monitor.